How to Keep Heat Pump from Freezing in Winter

When your house revolts, we help you restore order.

On this page

Quick answer

To prevent your heat pump from freezing, ensure the outdoor coil is clean and free of debris, check the refrigerant level, and verify the fan is operating correctly. Regular maintenance and proper airflow are key to avoiding ice buildup.

Confirm the symptom

Tools and prep

Step-by-step troubleshooting

  1. Inspect the Outdoor Coil
    Do: Visually check the outdoor coil for frost or ice buildup.
    Observe: Significant ice or frost on the coil.
    Means: The defrost cycle may not be functioning properly or airflow is restricted.
    Next: Clean the coil and check the defrost system.
  2. Clean the Coil and Surrounding Area
    Do: Use a soft-bristle brush or vacuum to remove dirt, leaves, and debris from the coil and around the unit.
    Observe: Improved airflow after cleaning.
    Means: Debris was restricting airflow, causing the coil to freeze.
    Next: Check the fan operation.
  3. Check Fan Operation
    Do: Turn the power back on and observe the fan to ensure it is spinning freely and at the correct speed.
    Observe: Fan is not spinning or is spinning erratically.
    Means: A faulty fan motor or capacitor could be the issue.
    Next: Test the fan motor and capacitor.
  4. Test Fan Motor and Capacitor
    Do: Use a multimeter to test the fan motor and capacitor for continuity and proper voltage.
    Observe: No continuity or incorrect voltage readings.
    Means: The motor or capacitor is likely faulty and needs replacement.
    Next: Replace the faulty component.
  5. Check Refrigerant Levels
    Do: Use a refrigerant gauge to check the refrigerant level in the system.
    Observe: Low refrigerant levels or visible leaks.
    Means: Low refrigerant can cause the coil to freeze due to low pressure.
    Next: Contact a professional HVAC technician to recharge or repair the system.
  6. Verify Thermostat Settings
    Do: Ensure the thermostat is set to 'Heat' mode and the temperature is set appropriately for the outdoor conditions.
    Observe: Thermostat is in 'Cool' mode or set too low.
    Means: Incorrect thermostat settings can cause the system to operate inefficiently.
    Next: Adjust the thermostat settings as needed.

Common causes

CauseLikelihoodDifficultyPart often needed
Dirty or clogged outdoor coil
Restricted airflow over the coil causes it to freeze.
CommonEasyNone
Low refrigerant levels
Low refrigerant causes the coil to operate at a lower temperature, leading to freezing.
CommonHardRefrigerant
Faulty defrost control board
The defrost cycle doesn't activate, allowing ice to build up.
SometimesMediumDefrost control board
Malfunctioning fan motor or capacitor
Improper airflow due to a non-functioning fan leads to coil freezing.
SometimesMediumFan motor or capacitor
Incorrect thermostat settings
Improper settings can cause the system to work inefficiently, leading to freezing.
SometimesEasyNone
Blocked airflow around the unit
Snow, ice, or debris around the unit restricts airflow.
CommonEasyNone

Parts matching

If your heat pump is freezing, you may need to replace these parts:

Always refer to your heat pump’s owner’s manual for specific part numbers and installation instructions.

When to call a professional

FAQ

How often should I clean my heat pump’s outdoor coil?

Clean the outdoor coil at least once a year, preferably in the fall before winter, and more often if you live in a dusty or high-pollen area.

Can I use a pressure washer to clean the outdoor coil?

No, using a pressure washer can damage the delicate fins on the coil. Use a soft-bristle brush or vacuum instead.

What is the defrost cycle, and how does it work?

The defrost cycle is an automatic process that melts ice buildup on the outdoor coil. It activates based on temperature and humidity sensors, temporarily switching the system to cooling mode to melt the ice.

Why is my heat pump making a clicking noise during the defrost cycle?

A clicking noise during the defrost cycle is normal and indicates the system is switching modes. However, excessive or unusual noises may indicate a problem with the defrost control board or other components.

Can a dirty air filter cause my heat pump to freeze?

Yes, a dirty air filter can restrict airflow, causing the indoor coil to freeze. Regularly cleaning or replacing the air filter can help prevent this issue.