Repair Riot

Heat Pump Not Heating

When your house revolts, we help you restore order.

On this page

Quick answer

Check the thermostat settings, ensure the power is on, and verify the air filter is clean. If the issue persists, inspect the emergency heat setting and outdoor unit for obstructions.

Confirm the symptom

Tools and prep

Step-by-step troubleshooting

  1. Check Thermostat Settings
    Do: Verify the thermostat is set to 'Heat' mode and the desired temperature is higher than the current room temperature.
    Observe: Thermostat displays correct settings and responds to changes.
    Means: Thermostat is functioning correctly.
    Next: If settings are correct, proceed to the next step.
  2. Inspect Power Supply
    Do: Ensure the heat pump's circuit breaker is on and the outdoor unit's power switch is in the 'On' position.
    Observe: Power is restored to both indoor and outdoor units.
    Means: Power supply is not the issue.
    Next: If power is on, continue troubleshooting.
  3. Check Air Filter
    Do: Remove and inspect the air filter for dirt or blockage.
    Observe: Air filter is clean or needs replacement.
    Means: A dirty filter may restrict airflow and reduce heating efficiency.
    Next: Replace the filter if necessary and test the heat pump again.
  4. Verify Emergency Heat
    Do: Check if the thermostat is set to 'Emergency Heat' mode and adjust it to 'Heat' if needed.
    Observe: Thermostat switches to normal heating mode.
    Means: Emergency heat mode was engaged, which may limit normal operation.
    Next: Wait a few minutes to see if heating resumes.
  5. Inspect Outdoor Unit
    Do: Use a ladder to safely check the outdoor unit for ice buildup, debris, or obstructions.
    Observe: Outdoor unit is clear of obstructions and free of ice.
    Means: No physical blockage is preventing proper operation.
    Next: If the unit is clear, proceed to the next step.
  6. Test Auxiliary Heat
    Do: Increase the temperature setting on the thermostat to activate auxiliary heat and observe if the system responds.
    Observe: Auxiliary heat engages and the system starts heating.
    Means: The auxiliary heat function is working correctly.
    Next: If auxiliary heat does not engage, consider professional assistance.

Common causes

CauseLikelihoodDifficultyPart often needed
Incorrect Thermostat Settings
The thermostat is not set to 'Heat' or the temperature is not set high enough.
CommonEasyNone
Power Supply Issues
The heat pump's circuit breaker is tripped or the outdoor unit's power switch is off.
CommonEasyNone
Dirty Air Filter
A clogged air filter restricts airflow, reducing heating efficiency.
CommonEasyAir Filter
Emergency Heat Mode Activated
The thermostat is set to 'Emergency Heat', which may limit normal heating operation.
SometimesEasyNone
Outdoor Unit Obstruction
Debris, ice, or snow blocks the outdoor unit, preventing proper heat exchange.
SometimesEasy–MediumNone
Refrigerant Leak
Low refrigerant levels prevent the heat pump from transferring heat effectively.
SometimesHardRefrigerant (Professional Service)
Faulty Defrost Timer
The defrost timer fails to initiate the defrost cycle, causing ice buildup on the outdoor unit.
RareHardDefrost Timer (Professional Service)
Thermostat Malfunction
A faulty thermostat may not send the correct signals to the heat pump.
RareMediumThermostat
Compressor Issues
A malfunctioning compressor cannot circulate refrigerant, preventing heat production.
RareHardCompressor (Professional Service)
Electrical Problems
Loose or damaged electrical connections disrupt the heat pump's operation.
RareHardElectrical Components (Professional Service)

Parts matching

Common parts needed for a heat pump not heating issue include:

Always replace parts with manufacturer-recommended equivalents and consider professional installation for complex components.

When to call a professional

FAQ

Can a dirty air filter cause my heat pump to stop heating?

Yes, a clogged air filter restricts airflow, reducing heating efficiency and potentially causing the system to overheat or malfunction.

What is emergency heat mode, and when should I use it?

Emergency heat mode uses electric resistance heating as a backup. Use it only if the heat pump fails to provide heat during extreme cold.

Why is my heat pump running but not blowing warm air?

This could be due to incorrect thermostat settings, a refrigerant leak, or a malfunctioning compressor. Check settings first, then consider professional help.

How often should I replace my air filter?

Replace the air filter every 1–3 months, depending on usage and environmental factors, to maintain optimal airflow and efficiency.

Can I fix a refrigerant leak myself?

No, refrigerant leaks require professional repair due to environmental regulations and the need for specialized equipment.

What should I do if my outdoor unit is iced over?

Turn off the power to the unit and allow the ice to melt naturally. Avoid using sharp objects to remove ice, as this can damage the unit.