Heat Pump Blows Cold Air on Heat

When your house revolts, we help you restore order.

On this page

Quick answer

If your heat pump blows cold air while heating, check the thermostat settings, ensure the unit is in heating mode, and verify the outdoor unit isn't frozen. If these don't resolve the issue, inspect the refrigerant levels and electrical connections.

Confirm the symptom

Tools and prep

Step-by-step troubleshooting

  1. Check Thermostat Settings
    Do: Verify the thermostat is set to 'Heat' mode and the desired temperature is higher than the room temperature.
    Observe: Thermostat displays correct settings and temperature.
    Means: Thermostat is functioning correctly if settings are correct.
    Next: If settings are correct, proceed to the next step. If not, adjust and wait 15 minutes to see if heating resumes.
  2. Inspect Outdoor Unit
    Do: Check the outdoor unit for ice or frost buildup. If present, allow it to defrost naturally or use a defrost cycle if your unit has one.
    Observe: Outdoor unit is free of ice or frost.
    Means: Frost or ice is not causing the issue.
    Next: If the unit is defrosted, proceed to the next step. If ice remains, check for refrigerant issues.
  3. Verify Electrical Connections
    Do: Turn off power to the heat pump. Inspect the electrical connections in the outdoor and indoor units for looseness or corrosion.
    Observe: Connections are secure and free of corrosion.
    Means: Electrical issues are not causing the problem.
    Next: If connections are good, proceed to the next step. If not, tighten or replace as needed and restore power to test.
  4. Check Refrigerant Levels
    Do: Using a refrigerant gauge, check the refrigerant levels. If low, look for signs of leaks using a refrigerant leak detector.
    Observe: Refrigerant levels are within the manufacturer's specifications.
    Means: Refrigerant is at the correct level if within range.
    Next: If refrigerant is low, contact a professional technician. If levels are correct, proceed to the next step.
  5. Test the Reversing Valve
    Do: Use a multimeter to test the reversing valve coil for continuity. If no continuity, the valve may be faulty.
    Observe: Multimeter shows continuity across the reversing valve coil.
    Means: Reversing valve is functioning if continuity is present.
    Next: If no continuity, the reversing valve may need replacement. If continuity is present, proceed to the next step.
  6. Inspect Air Filter and Ducts
    Do: Check the air filter for dirt or blockage. Inspect ducts for leaks or blockages that could reduce airflow.
    Observe: Air filter is clean, and ducts are intact and unobstructed.
    Means: Airflow issues are not causing the problem.
    Next: If everything is clear, the issue may be with the heat pump's internal components. Contact a professional for further diagnosis.

Common causes

CauseLikelihoodDifficultyPart often needed
Low Refrigerant
Low refrigerant levels prevent proper heat transfer, causing the system to blow cold air.
CommonHardRefrigerant charge
Frosted Outdoor Unit
Ice buildup on the outdoor unit restricts airflow and heat exchange, leading to cold air output.
CommonEasyDefrost cycle activation
Faulty Reversing Valve
A malfunctioning reversing valve can't switch the system to heating mode, resulting in cold air.
SometimesMediumReversing valve
Dirty Air Filter
A clogged air filter restricts airflow, reducing heating efficiency and causing cold air output.
CommonEasyAir filter replacement
Thermostat Issues
Incorrect thermostat settings or a faulty thermostat can prevent the system from heating properly.
SometimesEasyThermostat calibration or replacement
Electrical Problems
Loose or corroded electrical connections can disrupt the system's operation, leading to cold air output.
SometimesMediumElectrical connections or components
Duct Leaks
Leaky ducts allow heated air to escape before reaching the vents, resulting in cold air feeling.
SometimesMediumDuct sealing materials

Parts matching

Common parts needed for heat pump issues that cause cold air output include:

Always match parts to your heat pump's model and specifications. Consult the owner's manual or a professional for accurate part selection.

When to call a professional

FAQ

Can a dirty air filter cause my heat pump to blow cold air?

Yes, a clogged air filter restricts airflow, reducing heating efficiency and causing the system to blow cold air. Replace or clean the filter regularly.

Why is my heat pump running but not heating the house?

This could be due to low refrigerant, a faulty reversing valve, or thermostat issues. Check these components and consult a professional if needed.

How do I know if my heat pump needs refrigerant?

Signs include reduced heating performance, ice buildup on the outdoor unit, and unusual noises. A professional technician should check refrigerant levels.

Is it normal for the outdoor unit to blow cold air in heating mode?

No, in heating mode, the outdoor unit should absorb heat from the air. If it's blowing cold air, there may be an issue with the refrigerant or reversing valve.

Can I fix a faulty reversing valve myself?

Replacing a reversing valve requires specialized tools and knowledge. It's best to hire a professional HVAC technician for this repair.