Repair Riot

Furnace Not Lighting Burners

When your house revolts, we help you restore order.

On this page

Quick answer

Check the gas supply is on, relight the pilot if needed, and ensure the thermostat is set correctly. If the furnace still won't light, inspect the ignition system or call a professional.

Confirm the symptom

Tools and prep

Step-by-step troubleshooting

  1. Check Gas Supply
    Do: Verify the gas valve is fully open and there's no gas leak smell.
    Observe: Gas smell or hissing sound indicates a leak.
    Means: Gas leak is dangerous; shut off gas and call a professional.
    Next: If no leak, proceed to next step.
  2. Inspect Thermostat Settings
    Do: Set thermostat to 'Heat' and increase the temperature above room temperature.
    Observe: Furnace does not respond to thermostat changes.
    Means: Thermostat may be faulty or not properly connected.
    Next: Check thermostat wiring and connections.
  3. Check Pilot Light
    Do: Look through the access panel to see if the pilot light is lit.
    Observe: Pilot light is out or flickering.
    Means: Pilot light needs to be relit or the thermocouple may be faulty.
    Next: Attempt to relight the pilot light.
  4. Relight Pilot Light
    Do: Follow the manufacturer's instructions to relight the pilot light.
    Observe: Pilot light stays lit after relighting.
    Means: Pilot light issue was resolved.
    Next: Wait for furnace to attempt to ignite burners.
  5. Check Ignition System
    Do: Inspect the ignition system for damage or wear (look for a faulty igniter or flame sensor).
    Observe: Igniter does not glow or flame sensor is dirty.
    Means: Ignition system components may need cleaning or replacement.
    Next: Clean the flame sensor or replace the igniter if necessary.
  6. Test Furnace Operation
    Do: Turn the thermostat back to call for heat and observe the furnace.
    Observe: Burners ignite and furnace cycles normally.
    Means: Issue was resolved.
    Next: Monitor the furnace for consistent performance.

Common causes

CauseLikelihoodDifficultyPart often needed
Gas Supply Issue
Gas valve is closed or there's a leak in the gas line.
CommonEasyGas valve repair or replacement
Faulty Thermostat
Thermostat is not sending a signal to the furnace.
SometimesEasy–MediumThermostat replacement
Pilot Light Out
Pilot light is extinguished or thermocouple is faulty.
CommonEasyThermocouple replacement
Dirty Flame Sensor
Flame sensor is dirty and not detecting the flame.
SometimesEasyFlame sensor cleaning
Failed Igniter
Igniter is cracked or worn and cannot produce a spark.
SometimesMediumIgniter replacement
Electrical Issues
Loose or damaged wiring in the furnace control board.
RareHardControl board inspection or replacement

Parts matching

Common parts needed for a furnace not lighting burners include:

Always refer to your furnace's owner's manual for part compatibility and installation instructions.

When to call a professional

FAQ

Why won't my furnace light even though the pilot is on?

The flame sensor may be dirty or faulty, preventing the furnace from detecting the flame and igniting the burners.

Can a bad thermostat cause the burners not to light?

Yes, a faulty thermostat may not send the correct signal to the furnace to start the ignition process.

Is it safe to relight the pilot light myself?

Yes, if you follow the manufacturer's instructions carefully. If you're unsure, call a professional.

How often should I replace the thermocouple?

Thermocouples typically last 8–10 years, but should be inspected annually during furnace maintenance.

What should I do if I smell gas but there's no flame?

Immediately shut off the gas supply, ventilate the area, and call a professional HVAC technician or gas company.