Breaker Interlock for Generator: Installation & Troubleshooting Guide

When your house revolts, we help you restore order.

On this page

Quick answer

A breaker interlock ensures safe generator use by preventing backfeeding. Install it by aligning the interlock kit with the main and generator breakers, securing it in place, and verifying that it blocks both breakers from being on simultaneously.

Confirm the symptom

Tools and prep

Step-by-step troubleshooting

  1. Turn Off Power
    Do: Shut off the main breaker to disconnect power from the utility grid.
    Observe: The home’s electrical system is de-energized.
    Means: You can now work safely without risk of electric shock.
    Next: Install the interlock kit
  2. Install the Interlock Kit
    Do: Align the interlock bracket with the main and generator breakers. Secure it using the provided screws.
    Observe: The interlock physically prevents both breakers from being on at the same time.
    Means: The interlock is properly installed and functional.
    Next: Test the interlock
  3. Test the Interlock
    Do: Attempt to turn on both the main and generator breakers simultaneously.
    Observe: The interlock prevents both breakers from being on at the same time.
    Means: The interlock is working correctly.
    Next: Connect the generator
  4. Connect the Generator
    Do: Plug the generator into the transfer switch or connect it directly to the generator breaker.
    Observe: Power flows from the generator to the home’s electrical system.
    Means: The generator is supplying power safely.
    Next: Verify operation
  5. Verify Operation
    Do: Turn on the generator breaker and check for power in the home.
    Observe: The main breaker remains off, and the generator powers the home.
    Means: The system is operating as intended.
    Next: Final inspection
  6. Final Inspection
    Do: Double-check all connections and ensure the interlock is securely fastened.
    Observe: All components are properly installed and secure.
    Means: The system is ready for use.
    Next: Complete

Common causes

CauseLikelihoodDifficultyPart often needed
Improper installation
The interlock may not be aligned correctly or secured tightly.
CommonEasy–MediumBreaker interlock kit
Worn or damaged interlock
Over time, the interlock mechanism can become loose or broken.
SometimesEasyReplacement interlock
Incorrect breaker size
Using a breaker that is not compatible with the interlock can prevent proper function.
SometimesMediumCorrect-sized breaker
Generator not grounded
Improper grounding can cause electrical issues and prevent safe operation.
RareMediumGrounding kit
Faulty transfer switch
A malfunctioning transfer switch can interfere with the interlock’s operation.
RareHardTransfer switch repair or replacement
Loose connections
Loose wiring connections can cause power interruptions or prevent the generator from supplying power.
SometimesEasy–MediumWire connectors or terminal blocks
Incorrect generator setup
The generator may not be properly configured for use with the interlock system.
SometimesMediumGenerator manual or setup guide

Parts matching

Match your symptoms to the most likely parts needed for a breaker interlock system:

Always verify the compatibility of the interlock kit with your electrical panel and generator model before purchasing.

When to call a professional

FAQ

What is a breaker interlock for a generator?

A breaker interlock is a mechanical device that prevents the main utility breaker and the generator breaker from being on at the same time, ensuring safe operation and preventing backfeeding into the grid.

Can I install a breaker interlock myself?

Yes, if you have basic electrical knowledge and follow safety procedures. However, it is recommended to consult a licensed electrician if you are unsure.

Do I need a permit to install a breaker interlock?

Local codes may require a permit for electrical work. Check with your local authorities before installation.

How do I know if my interlock is working properly?

Test the interlock by attempting to turn on both the main and generator breakers. If the interlock prevents this, it is functioning correctly.

Can I use any generator with a breaker interlock?

The generator must be compatible with the interlock system and sized appropriately for your home’s electrical needs.

What are the safety risks of not using an interlock?

Not using an interlock can result in backfeeding, which can damage the generator, cause electrical fires, or endanger utility workers.